ITT 801P5 Manual do Utilizador Página 43

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 42
Page 39 801P5 Smart Switch
TM
Range
No.
Operating
Range
bar
Increasing
Range
bar
Deadband
Percent of
Full Scale
Minimum
Decreasing
Setpoint
bar
Max
Operating
Pressure
bar
Proof
Pressure
bar
22 0 - 350
mB
7 - 350
mB
1-99 3.5 mB 0.86 1.7
24 0 - 1000
mB
20 - 1000
mB
1-99 10 mB 2.6 5.1
25 0 - 2 0.04 - 2 1-99 0.02 5.2 10.3
27 0 - 6.5 0.013 - 6.5
1-99 0.065 17.2 34.4
29 0 - 17 0.34 - 17
1-99 0.17 43.1 51.7
31 0 - 35 0.7 - 35 1-99 0.35 103 103
32 0 - 65 1.3 - 65 1-99 0.65 172 206
34 0 - 200 4 - 200 1-99 2 206 344
Range
No.
Operating
Range
in H
2
O
In
creasing
Range
in H
2
O
Deadband
Percent of
Full Scale
Minimum
Decreasing
Setpoint
in H
2
O
Max
Operating
Pressure
psig
Proof
Pressure
psig
72 0 - 100 2 - 100 1-99 1 12.5 25
74 0 - 415 8.3 - 415
1-99 4.15 37.5 75
Total Accuracy
± 0.2% F.S.O., including linearity, hysteresis, repeatability, and
temperature
Vista de página 42
1 2 ... 38 39 40 41 42 43 44 45

Comentários a estes Manuais

Sem comentários